Rooftop Units in Brookfield, WI
Rooftop Units in Brookfield, WI
Commercial rooftop HVAC units are a common, cost-effective choice for businesses in Brookfield, WI. Proper installation, timely replacement, and regular maintenance of these units keep offices, retail spaces, and light industrial facilities comfortable year-round while protecting rooftop structures from snow loads and freeze-thaw damage.

Why rooftop unit attention matters in Brookfield
Brookfield’s humid summers and cold, snowy winters put unique stresses on rooftop equipment. High summer humidity increases runtime and condensate volume; winter freeze-thaw cycles and heavy snow loads can compromise curbs, drains, and rooftop access. Addressing rooftop unit issues proactively reduces emergency breakdowns, prevents water intrusion into the building, and extends equipment life—critical for buildings where unit failure directly affects occupants and operations.
Common rooftop unit issues in Brookfield
- Insufficient cooling or heating: Often caused by refrigerant leaks, failing compressors, dirty coils, or airflow restrictions.
- Short cycling: Rapid on/off cycles that stress compressors and increase energy use; common causes include control issues or oversized equipment.
- Electrical faults: Burnt contacts, starter failures, or degraded wiring accelerated by moisture and temperature swings.
- Frozen coils and drain backups: Blocked condensate drains or low airflow can freeze coils, especially during early spring or fall.
- Economizer failures: Stuck dampers or faulty sensors prevent free cooling and reduce energy savings.
- Structural leaks and curb deterioration: Water infiltration, corrosion, and damaged flashings around the curb lead to roof leaks and insulation damage.
Rooftop unit service types and diagnostic approach
Proper servicing begins with a comprehensive diagnostic walk-through tailored to commercial rooftops:
- Visual inspection of unit casing, curb condition, flashing, and roof penetrations to spot corrosion, rust, or seal failures.
- Operational checks: observe start-up, run cycles, compressor behavior, fan speeds, and thermostat interaction.
- Electrical testing: voltage, amp draws, contactor and motor condition, and control board checks.
- Refrigeration system evaluation: refrigerant pressures, leak detection, and compressor health.
- Airflow assessment: filter condition, belt tensions (if applicable), and duct connection integrity.
- Drain and coil inspection: clean coils, clear condensate lines, and verify proper slope and trap condition.
Diagnostics produce a clear replacement vs. repair recommendation, factoring in unit age, lifecycle costs, energy code requirements, and downtime risks.
Installation and replacement process (typical)
- Site survey and load calculation to size the right unit and identify curb or roof reinforcement needs.
- Structural review for rooftop load capacity, crane placement planning, and roof walk path to protect roofing membrane.
- Permitting and documentation aligned with Brookfield and Wisconsin commercial building requirements.
- Removal of the existing unit, curb modifications or curb adapter installation, and secure mechanical and electrical connections.
- Start-up, refrigerant charging, controls integration, and commissioning to verify performance and indoor comfort levels.
- Final inspection and operational testing under expected load conditions.
Curb and structural considerations
- Curb condition: Damaged or undersized curbs cause poor sealing, vibration transfer, and roof leaks. Curb replacement or use of curb adapters often required when units are upgraded.
- Roof structure: Verify that the roof’s framing and decking can support unit weight plus crane loads. Reinforcement may be necessary for heavier modern units.
- Vibration isolation: Proper pads or spring isolators reduce transmitted noise and protect the roof membrane.
- Roof penetrations and flashing: Ensure all penetrations are sealed with approved flashings to avoid water infiltration, a frequent cause of interior damage in Brookfield’s freeze-thaw environment.
Economizer, controls, and efficiency upgrades
- Economizer retrofits: Properly working economizers provide free cooling on mild days and reduce compressor runtime; ensure dampers, actuators, and sensors are maintained or replaced when failing.
- Control upgrades: Upgrading to digital controls or integrating units into a Building Management System (BMS) enables better scheduling, fault detection, and energy reporting.
- Variable components: Replacing PSC motors with ECM fans, or adding variable-speed drives and staged compressors, significantly cuts energy consumption and improves comfort.
- Demand-controlled ventilation: CO2 sensors and occupancy-based control limit outside air when unneeded, cutting heating/cooling loads while preserving IAQ.
Safety and rooftop access procedures
Working on rooftop units requires strict safety protocols:
- Use fall protection, secure ladders, and verify rooftop stability before technician access.
- Plan crane lifts with a licensed rigger and confirm roof load zones to avoid membrane damage.
- Lockout/tagout electrical sources and test for live circuits; cold-weather electrical hazards increase risk of contact failures.
- Protect rooftop rooflife and walking paths to prevent rooftop leaks and maintain warranty conditions.
Compliance and local code considerations
- All installations and replacements should comply with State of Wisconsin commercial building standards and Brookfield municipal ordinances governing rooftop equipment, noise limits, and setback requirements.
- Energy codes and local requirements may mandate high-efficiency equipment, economizer functionality, or specific control strategies for larger systems.
- Proper permits, inspections, and documentation ensure code compliance and can be essential for insurance and warranty claims.
Long-term benefits and maintenance recommendations
Routine, preventive maintenance reduces unexpected failures and improves energy efficiency. Recommended practices for Brookfield properties:
- Biannual or seasonal tune-ups: spring for cooling readiness, fall for heating checks.
- Regular filter changes, coil cleaning, and condensate drain clearing to prevent capacity loss and indoor air quality issues.
- Annual refrigerant leak checks and electrical inspections to catch problems early.
- Maintain detailed records of service, parts replaced, and performance trends to inform lifecycle and replacement planning.
- Consider predictive monitoring where sensor data highlights emerging issues before they cause downtime.
Keeping rooftop units well maintained and appropriately upgraded for Brookfield’s climate protects occupant comfort, reduces energy costs, and prevents rooftop and interior building damage. A structured approach—inspection, diagnosis, compliant installation or repair, and scheduled maintenance—delivers reliable performance and better total cost of ownership for your commercial building.
Maintenance Plan
SILVER PLAN (Heating & cooling packages
Our Silver Plan provides you with year-round, worry-free protection. The benefits include:
$129.95
/plan cost every 6 months
Inspection and cleaning of your system during service visits.
Next-day scheduling & 24-hour emergency service.
Full coverage for labor on repairs due to equipment failure.
15% Discount on all parts for repairs and upgrades.
15% Discount on additional system installation.

2
visits per year
1
year in duration
15%
discount on jobs
Cooling
Lubricate motors
Clean condensate line
Check fan belts
Check performance of system
Change filters
Check contactor points
Check evaporator air temperatures
Check pressure switches
Check wiring & connections
Clean condenser coil
Check refrigerant charge
Check temperature differential
Check operating pressures
Check evaporator coil
Check voltage and AMP draw
Heating
Lubricate motors
Check wiring & connections
Adjust controls if needed
Clean burners/flame sensor.
Adjust combustion air to burners
Check Ohms and amps of furnace
Check blower
Check heat exchanger for cracks (if accessible)
Change filters, standard pleated filters included
Check performance of system
Check air temperature rise
Check C.O. levels