Commercial rooftop units are the backbone of HVAC for many Germantown businesses — from retail centers and offices to schools and light industrial buildings. Proper installation, timely replacement, and routine preventative maintenance keep these packaged rooftop HVAC systems operating efficiently through hot, humid summers and freezing, snowy Wisconsin winters.

Why rooftop unit care matters in Germantown, WI
Germantown’s climate places unique stresses on rooftop equipment. Summer humidity increases compressor runtime and condensate loads. Winter cold, ice, and heavy snow increase structural loading and create freeze/thaw cycles that affect seals, drains, and curbs. In addition, seasonal temperature swings strain control systems and can accelerate wear on belts, bearings, and electrical components. Regular professional attention reduces downtime, maintains indoor comfort, and extends equipment life.
Common rooftop unit issues in Germantown
- Reduced cooling capacity during humid months due to dirty coils or low refrigerant.
- Frequent freeze-ups or icing of condensate lines in shoulder seasons.
- Water intrusion and roof leaks from failed curb seals or improper flashing after maintenance or replacement.
- Compressor failure or frequent short cycling, often caused by electrical issues, dirty coils, or improper charge.
- Damaged or misaligned curb adapters after equipment changeouts or high-wind events.
- Economizer malfunctions, leading to indoor humidity problems or wasted energy.
- Control communication failures between rooftop units and building automation systems.
Service types and what to expect
Installation and replacement
- Comprehensive site survey to confirm roof access, curb condition, crane requirements, and nearby obstructions.
- Verification of structural capacity for equipment weight plus local snow loads; coordination with structural engineer when needed.
- Use of manufacturer-approved curb adapters and curb flashing to ensure water tightness and thermal integrity.
- Proper duct and piping connections, gas and electrical terminations, and startup commissioning to manufacturer specs.
- Refrigerant handling in compliance with current regulations and consideration of refrigerant availability or retrofit needs for older systems.
Installation should prioritize long-term serviceability: clear access panels, safe fall protection anchor points, and routing that allows future maintenance without roof disturbance.
Preventative maintenance
- Recommended frequency: at least two visits per year—pre-summer and pre-winter. High-use or older units may need quarterly checks.
- Typical PM checklist: coil cleaning, filter replacement, belt and drive inspection, blower wheel cleaning, condenser and evaporator inspections, refrigerant level check, electrical tightening, motor lubrication, and verification of safety controls.
- Condensate management: clear drains, verify traps and heat trace if installed, and ensure proper slope and outlet integrity to prevent freeze-related backup.
- Documentation of findings and performance baselines to spot gradual declines in efficiency.
Preventative maintenance reduces emergency breakdowns, improves efficiency, and helps plan timely replacements.
Rooftop unit diagnostics
- Systematic diagnostics include airflow measurement, static pressures, fan motor amperage, refrigerant pressures and superheat/subcooling, and temperature split analysis.
- Control system diagnostics: checking sensor accuracy, thermostat and economizer calibration, damper actuation, and communication with building automation systems.
- Infrared inspection for electrical hot spots, motor temperature anomalies, and duct leakage.
- Root cause analysis for recurring problems such as short cycling, refrigerant loss, or unexpected energy consumption.
Accurate diagnostics allow targeted repairs that prevent repeated failures and reduce long-term costs.
Curb and structural considerations
- Verify curb dimensions, height, and attachment method before ordering new equipment. Custom curb adapters are often required for modern units.
- Evaluate roof membrane condition and flashing to prevent leaks during and after installation.
- Assess rooftop load capacity, and plan for snow load and wind uplift. Reinforcement or redistribution of loads may be necessary on older roofs.
- Plan safe access and staging for cranes and rigging, and ensure rooftop penetration points are sealed and insulated properly.
Failing to address curb and structural elements often leads to premature leaks, mechanical misalignment, and additional repair costs.
Economizer and control system servicing
- Economizers must be calibrated and maintained to ensure free cooling is used appropriately, maximizing energy savings without compromising humidity control.
- Controls servicing includes sensor calibration, firmware updates when applicable, verifying damper positions, and ensuring sequences of operation match occupancy and space usage.
- Integration with building automation or remote monitoring improves fault detection and allows performance-based maintenance scheduling.
Well-maintained controls and economizers can significantly reduce seasonal energy use and improve occupant comfort.
Safety and code compliance
- All rooftop work should comply with local and state building and mechanical codes, and follow manufacturer installation and service instructions.
- Safety practices include fall protection, lockout-tagout, proper gas piping installation, and ensuring combustion air and venting clearances are maintained for gas-fired packaged units.
- Refrigerant handling must meet environmental regulations and certified technician requirements.
- Documentation of inspections and code compliance supports insurance and municipal review processes.
Adhering to codes and safety standards minimizes liability and ensures reliable, lawful operation.
Lifecycle planning and replacement indicators
- Typical packaged rooftop unit life ranges from 12 to 20 years depending on maintenance, environment, and hours of operation.
- Replacement should be considered when units show frequent major failures, declining efficiency despite repairs, or contain obsolete refrigerants no longer supported by parts and supply chains.
- Lifecycle planning includes budgeting for staged replacements, upgrades to higher-efficiency equipment, options for variable speed drives, deferred refrigerant transition planning, and potential integration with modern control strategies.
- Energy modeling and return-on-investment analysis help prioritize replacements that deliver the best long-term savings.
Benefits of proactive rooftop unit management
- Greater system reliability and fewer emergency repairs during peak seasons.
- Improved energy efficiency and lower utility costs from well-tuned equipment and economizer use.
- Extended equipment life and predictable capital planning through early detection of issues.
- Reduced risk of roof leaks and structural damage through proper curb treatment and installation practices.
- Safer work environment and assured compliance with codes and regulations.
Practical maintenance tips for Germantown buildings: schedule a thorough spring commissioning before cooling season, perform a fall check focused on heating components and snow load preparedness, and monitor compressor runtime and energy use trends to catch declines early. Regular, documented service preserves comfort for occupants and protects commercial assets from avoidable failures.
Maintenance Plan
SILVER PLAN (Heating & cooling packages
Our Silver Plan provides you with year-round, worry-free protection. The benefits include:
$129.95
/plan cost every 6 months
Inspection and cleaning of your system during service visits.
Next-day scheduling & 24-hour emergency service.
Full coverage for labor on repairs due to equipment failure.
15% Discount on all parts for repairs and upgrades.
15% Discount on additional system installation.

2
visits per year
1
year in duration
15%
discount on jobs
Cooling
Lubricate motors
Clean condensate line
Check fan belts
Check performance of system
Change filters
Check contactor points
Check evaporator air temperatures
Check pressure switches
Check wiring & connections
Clean condenser coil
Check refrigerant charge
Check temperature differential
Check operating pressures
Check evaporator coil
Check voltage and AMP draw
Heating
Lubricate motors
Check wiring & connections
Adjust controls if needed
Clean burners/flame sensor.
Adjust combustion air to burners
Check Ohms and amps of furnace
Check blower
Check heat exchanger for cracks (if accessible)
Change filters, standard pleated filters included
Check performance of system
Check air temperature rise
Check C.O. levels