Commercial rooftop HVAC units are a core part of comfort and indoor air quality for Mequon businesses. With our region's cold winters, humid summers, and lake influence from Lake Michigan, rooftop units face unique stresses that make proper selection, installation, and maintenance essential.

Why rooftop units matter in Mequon
Rooftop units, or RTUs, centralize heating, cooling, and ventilation on the roof to save interior floor space and simplify duct routing. In Mequon, rooftop installations must also contend with:
- Heavy snow and ice loads during winter and freeze-thaw cycles that can compromise curbs and roof penetrations.
- Salt spray and deicing chemicals along roadways that accelerate corrosion of metal components.
- Temperature swings that stress seals, gaskets, and refrigerant systems.Selecting the right unit and installing it correctly reduces downtime, limits roof damage, and improves energy efficiency across seasons.
Common rooftop unit issues in Mequon
Commercial property owners in Mequon commonly see these RTU problems:
- Frozen evaporator or condensate lines in cold snaps, causing blocked drains and indoor humidity issues.
- Corrosion of coils and frames due to salt and moisture exposure, shortening component life.
- Roof leaks and membrane damage at the curb interface from improper flashing or deteriorated seals.
- Compressor or fan motor failure accelerated by temperature extremes and inadequate maintenance.
- Reduced efficiency from clogged coils, dirty filters, or refrigerant leaks after long service intervals.Being aware of these local failure modes helps prioritize inspections and mitigation strategies.
Unit selection and sizing for Mequon buildings
Choosing the right rooftop unit is critical:
- Perform a professional load calculation that accounts for Mequon climate, building orientation, glazing, insulation, occupancy, and equipment heat loads.
- Match unit capacity with actual load, not rule-of-thumb sizing. Oversizing increases short cycling and moisture problems; undersizing causes comfort complaints.
- Consider efficiency metrics relevant to rooftop units such as SEER, EER, and HSPF for packaged units, plus variable-speed fans and staged compressors for improved control.
- Evaluate fuel options and controls: gas heat for reliable winter performance, electric heat where gas is not available, and integrated economizers or energy recovery ventilators when ventilation demands are high.
- Select corrosion-resistant materials and coatings for exposed components in coastal-influenced climates near Lake Michigan.
Rooftop mounting, curbs, and roof considerations
Proper rooftop mounting protects both the RTU and the roof assembly:
- Inspect roof structure and membrane before selecting curb type. Verify roof load capacity for equipment and crane operations.
- Use manufacturer-rated roof curbs and curb adapters sized to the unit. Improper curbs are a leading cause of roof leaks.
- Ensure curb flashing and sealants are compatible with the membrane type and are installed to local code standards.
- Include vibration isolators and flexible connections to minimize transmitted loads and prevent roof membrane damage.
- Confirm unit access and service clearance, and plan for safe rooftop walkways and fall protection anchors per OSHA and local code.
Crane and permitting logistics in Mequon
Rooftop replacements require planning:
- Coordinate crane placement, load path, and lift plan with local authorities and neighboring properties to accommodate narrow streets or business centers.
- Secure necessary building permits and any special crane permits. Mequon and Ozaukee County requirements vary by project scale.
- Plan for street or parking area closures, pedestrian protection, and utility locates well in advance to avoid delays.
- Schedule lifts during favorable weather windows to minimize risk from high winds, ice, or precipitation.
Weatherproofing and rooftop safety protocols
Long-term protection depends on attention to detail:
- Install proper flashing, curb caps, and tamper-resistant fasteners. Re-seal penetrations with compatible materials.
- Protect condensate drains with heat trace where freezing is a risk and ensure positive slope to roof drains.
- Use UV-stable protective finishes and corrosion inhibitors on exposed metal parts.
- Implement rooftop safety measures: guard rails, anchor points, and clear service paths. Ensure technicians follow fall protection and cold-weather safety procedures.
Preventive maintenance for rooftop equipment in Mequon
A proactive maintenance program extends RTU life and avoids costly downtime:
- Schedule seasonal inspections: pre-winter heating check and pre-summer cooling check, plus mid-season reviews.
- Typical maintenance tasks include filter replacement, coil cleaning, refrigerant charge verification, belt and motor inspection, lubrication, electrical connection tightening, and thermostat calibration.
- Inspect and clear condensate drains and pans, and verify heat trace where installed.
- Check curb seals and roof flashing annually and after major weather events.
- Maintain a service log with serial numbers, refrigerant history, motor hours, and parts replacements to support lifecycle planning.
Repair and replacement solutions
When repairs are needed, assess repair versus replacement based on age, efficiency, and reliability:
- Targeted repairs: compressor or motor replacement, control board repair, leak repair, or coil reconditioning can restore function when units are relatively young and otherwise reliable.
- Re-curbing, flashing repair, and roof membrane repair are commonly performed with rooftop unit maintenance to stop leaks and protect the building envelope.
- Replacement is warranted when units are near the end of typical RTU lifespans, show recurrent failures, or when energy-efficient upgrades will deliver meaningful operational savings.
- For replacements, plan for modern controls, staged equipment, and improved economizer or ventilation integration to reduce operating costs and improve occupant comfort.
Lifecycle planning and budgeting
Effective lifecycle planning protects property value and operational continuity:
- Typical rooftop packaged unit lifespan is 10 to 20 years depending on maintenance, environment, and load profile. In Mequon’s climate, aggressive maintenance and corrosion protection can extend useful life.
- Build capital replacement schedules that account for increasing refrigerant and control obsolescence, tighter energy codes, and potential for escalating repair costs as units age.
- Consider phased replacements and standardization across buildings to simplify parts inventory and service training.
- Track utility consumption and service trends to identify opportunities for upgrade to high-efficiency equipment, variable controls, or hybrid solutions.
Maintenance Plan
SILVER PLAN (Heating & cooling packages
Our Silver Plan provides you with year-round, worry-free protection. The benefits include:
$129.95
/plan cost every 6 months
Inspection and cleaning of your system during service visits.
Next-day scheduling & 24-hour emergency service.
Full coverage for labor on repairs due to equipment failure.
15% Discount on all parts for repairs and upgrades.
15% Discount on additional system installation.

2
visits per year
1
year in duration
15%
discount on jobs
Cooling
Lubricate motors
Clean condensate line
Check fan belts
Check performance of system
Change filters
Check contactor points
Check evaporator air temperatures
Check pressure switches
Check wiring & connections
Clean condenser coil
Check refrigerant charge
Check temperature differential
Check operating pressures
Check evaporator coil
Check voltage and AMP draw
Heating
Lubricate motors
Check wiring & connections
Adjust controls if needed
Clean burners/flame sensor.
Adjust combustion air to burners
Check Ohms and amps of furnace
Check blower
Check heat exchanger for cracks (if accessible)
Change filters, standard pleated filters included
Check performance of system
Check air temperature rise
Check C.O. levels