Surge Protection Maintenance in West Allis, WI
Surge Protection Maintenance in West Allis, WI
Protecting your home from electrical surges is essential in West Allis, WI where seasonal thunderstorms, winter ice storms, and local utility switching can expose HVAC systems and sensitive electronics to damaging transients. Surge protection maintenance ensures whole-home and point-of-use surge protective devices (SPDs) are functioning, replace worn components before failure, and keep warranties and coordinated protection intact so your furnace, air conditioner, smart appliances, and home office gear stay safe.

Why surge protection maintenance matters in West Allis homes
- West Allis experiences frequent summer storms and occasional lightning strikes that create high-energy transients.
- Winter events like ice storms and rapid load changes at the grid can produce damaging voltage spikes.
- Modern HVAC systems and electronics use sensitive controls and power electronics that fail when exposed to repeated surges.
- Without routine maintenance, SPDs (especially MOV based units) quietly degrade and can lose effectiveness over time.
Common surge protection issues in West Allis
- Tripped or failed whole-home SPDs with no visible indicator reset.
- Point-of-use protectors that show no protection despite recent power events.
- Corroded or loose connections at the service panel or SPD terminals.
- Degraded MOVs showing discoloration or bulging after repeated surges.
- Uncoordinated protection between service panel SPDs and downstream devices, leaving HVAC controls exposed.
- SPD failure after nearby lightning or major utility switching.
What surge protection maintenance includes
A professional surge protection maintenance visit in West Allis typically covers the following steps:
Visual inspection
- Check SPDs at the service panel, subpanels, meter base area if accessible, and point-of-use protectors (HVAC disconnects, furnace/air handler, refrigerator, entertainment center).
- Look for discoloration, bulging, burnt smells, or tripped indicators on surge modules.
Electrical testing
- Confirm continuity and conductor integrity to and from the SPD.
- Test clamping and response using manufacturer-recommended procedures when available.
- Use insulation resistance and leakage current checks to detect compromised MOVs or internal damage.
- Verify grounding system effectiveness since a poor ground reduces SPD performance.
Connection tightening and torque verification
- Tighten SPD line, neutral, and ground terminations to electrical torque specifications.
- Inspect lugs and bonding conductors for corrosion or heat-related damage.
Component condition checks
- Inspect MOVs, thermal disconnects, and indicator circuits for signs of wear.
- Verify surge counter readings and note cumulative surge events if the device has a counter.
Documentation and replacement criteria
- Record SPD model, serial, indicator status, counter value, and test results.
- Recommend replacements when indicators show failure, counters exceed thresholds, MOV discoloration or bulging is present, leakage is out of spec, or internal fusing/thermal disconnects have operated.
MOVs and component behavior explained simply
Metal oxide varistors or MOVs absorb surge energy by changing resistance under high voltage. They wear down over repeated surges. Early signs are a reduced clamping voltage and heat stress visible as discoloration or bulging. SPDs include thermal disconnects and visual indicators that show when MOVs have permanently degraded. Because MOV wear is cumulative, a unit that protected your home through several strong events may appear functional but no longer offers rated protection. Regular testing reveals hidden degradation before a failure damages connected equipment.
Replacement criteria and expected lifespan
- Typical lifespan of MOV-based SPDs varies widely with exposure: light use can last 5 to 10 years; frequent surge exposure may reduce life to 3 years or less.
- Replace a unit immediately if:
- Visual indicator shows failure.
- Surge counter exceeds manufacturer threshold.
- MOVs show physical damage or tests indicate elevated leakage current.
- Device fails basic clamping or continuity tests.
- Keep manufacturer warranty and life expectancy documentation handy; many SPDs carry 5 to 10 year warranties and may include connected-equipment protection policies with registration.
Preventative strategies to protect HVAC and electronics
- Install a coordinated, multi-stage protection system: a whole-home SPD at the service panel plus point-of-use SPDs at HVAC equipment and high-value electronics.
- Ensure a low-impedance, properly bonded grounding system. Ground quality is critical in West Allis where soil conditions and stranded older systems may need upgrades.
- Protect HVAC disconnects and control panels directly with dedicated SPDs to safeguard control boards and variable speed drives.
- Use surge-rated power strips with thermal fuses for home office equipment and entertainment systems in addition to whole-home protection.
- After a major storm or lightning event, schedule an inspection. Even if nothing appears wrong, internal SPD damage can occur.
Typical maintenance schedule
- Visual inspection and basic testing: annually for most residential systems.
- Full diagnostic (including insulation and leakage tests, surge counter review): every 2 to 3 years for homes with moderate surge exposure.
- Immediate inspection after significant events: any close lightning strike, ice storm, or utility switching incident.
- Review warranties and registration annually; register new SPDs to maintain connected equipment coverage.
Upgrade and system integration recommendations
- Consider coordinated protection: service entrance SPD plus subpanel and dedicated HVAC SPDs sized for the expected short-circuit current and surge exposure.
- Upgrade to SPDs with surge counters and remote monitoring capability when available to track cumulative energy absorption.
- Verify generator compatibility: automatic transfer switches and backup generators can introduce transients during switching. Use SPDs rated for generator systems or install transfer-switch rated protection.
- Integrate surge protection with whole-home electrical assessments. If your panel or grounding is older, combine SPD upgrades with grounding and bonding improvements to ensure full effectiveness.
Warranty and documentation considerations
- Keep SPD purchase and installation records, warranty cards, and surge counter readings. These documents are often required for connected-equipment warranties.
- Manufacturer warranties vary. Confirm coverage periods, replacement terms, and any connected-equipment limits.
- Professional maintenance records can support warranty claims and insurance inquiries following damage.
Maintenance Plan
SILVER PLAN (Heating & cooling packages
Our Silver Plan provides you with year-round, worry-free protection. The benefits include:
$129.95
/plan cost every 6 months
Inspection and cleaning of your system during service visits.
Next-day scheduling & 24-hour emergency service.
Full coverage for labor on repairs due to equipment failure.
15% Discount on all parts for repairs and upgrades.
15% Discount on additional system installation.

2
visits per year
1
year in duration
15%
discount on jobs
Cooling
Lubricate motors
Clean condensate line
Check fan belts
Check performance of system
Change filters
Check contactor points
Check evaporator air temperatures
Check pressure switches
Check wiring & connections
Clean condenser coil
Check refrigerant charge
Check temperature differential
Check operating pressures
Check evaporator coil
Check voltage and AMP draw
Heating
Lubricate motors
Check wiring & connections
Adjust controls if needed
Clean burners/flame sensor.
Adjust combustion air to burners
Check Ohms and amps of furnace
Check blower
Check heat exchanger for cracks (if accessible)
Change filters, standard pleated filters included
Check performance of system
Check air temperature rise
Check C.O. levels