info@alianceheatandcool.com

UV Air Treatment in Saukville, WI

UV air treatment in Saukville, WI improves indoor air quality by reducing microbes on coils and in-duct air; learn about installation and maintenance.

UV Air Treatment in Saukville, WI

Ultraviolet (UV) air treatment is an effective supplemental solution for improving indoor air quality and HVAC performance in Saukville, WI homes. Properly installed UV lamps reduce microbial growth on cooling coils and in the airstream, helping to control mold, bacteria, and odors that are common in humid summer months and in systems that run long hours.

UV Air Treatment in Saukville, WI

Why UV Air Treatment matters in Saukville, WI

Saukville experiences warm, humid summers and cool, damp spring and fall seasons. That climate encourages mold and biofilm growth on HVAC coils and inside ductwork. Biofilm on coils reduces heat transfer, increases energy use, and can spread spores and odors through the house. UV air treatment targets the microbial sources directly at the coil and within the airstream, reducing regrowth and keeping systems cleaner between professional coil cleanings. For homeowners concerned about allergies, musty smells, or declining system efficiency, UV is a targeted, low-profile option to improve overall air quality.

Where UV lamps are installed

  • Coil-mounted UV lamps: Installed just upstream of the evaporator coil or directly across the coil surface to continuously irradiate and prevent microbial and biofilm buildup on coil fins and drain pans. This is the most common placement for improving system efficiency and coil hygiene.
  • In-duct UV lamps: Mounted inside the main supply or return duct to treat the moving airstream. In-duct units reduce airborne microbes and can be sized to the airflow for effective exposure time.
  • Upper-air UV systems: Typically used in larger or commercial spaces to disinfect room air while minimizing direct exposure to occupants. Not commonly used in single-family homes but worth noting for shared spaces.

Differences between UV types

  • Low-pressure mercury lamps (254 nm): The most common residential option. Emit germicidal UV-C light that inactivates microorganisms. Effective for coil and in-duct applications. Lamp output declines with hours of use, so replacement is required on a regular schedule.
  • High-output UV-C lamps: Produce greater intensity for tighter spaces or high airflow systems. Often used for coil applications where stronger irradiation is needed.
  • Pulsed xenon systems: Emit broad-spectrum UV including shorter wavelengths. These can be effective but are more complex and may generate ozone unless specifically filtered.
  • Far-UVC (around 222 nm): An emerging technology with potential for safer occupied-space disinfection. Deployment in residential HVAC is limited and still evolving; placement and safety must be validated by manufacturers.

Choosing the right type depends on system configuration, airflow, and treatment goals. Low-pressure UV-C is the proven, typical selection for Saukville homes.

Expected indoor air quality improvements

  • Reduced microbial growth on coils and drain pans, which lowers musty odors and improves system airflow and efficiency.
  • Fewer airborne bacteria, mold spores, and some viruses traveling through the airstream, contributing to a cleaner-feeling home.
  • Reduced allergens and odors, especially during humid months when mold and biofilm thrive.
  • Improved HVAC performance as cleaner coils maintain heat exchange efficiency, which can reduce runtime and energy use over time.

Note that UV air treatment is not a standalone cure for all IAQ issues. It works best as part of a layered strategy including filtration, humidity control, and regular HVAC maintenance.

Performance testing and verification

  • UV intensity measurement: Using a UV-C light meter to confirm the lamp delivers specified intensity at the coil or duct surface.
  • Coil and drain pan inspection: Visual documentation or before-and-after photos to show reduction in biofilm and fouling.
  • ATP swab testing: Adenosine triphosphate testing can quantify biological contamination on surfaces before and after treatment.
  • Air sampling: Microbial or particle counts to evaluate airborne improvements when needed.
  • System performance checks: Monitoring airflow, temperature differentials, and energy use to identify efficiency gains after UV installation.

These tests confirm the system is functioning and help plan maintenance intervals based on real-world results.

Bulb replacement and recommended maintenance schedule

  • Lamp life: Most low-pressure UV-C lamps should be replaced annually because germicidal output falls well before the lamp visually fails. Some high-output lamps may have different intervals; follow manufacturer guidelines.
  • Quartz sleeve cleaning: If the lamp sits behind a quartz sleeve, clean the sleeve every 3 to 6 months in dusty or humid environments. Deposits on the sleeve reduce UV transmission.
  • Biannual inspections: At least twice a year inspect lamp operation, ballast condition, sleeve integrity, and lamp mounting. In Saukville, consider scheduling checks in spring and early fall to prepare for peak HVAC use.
  • Coil inspections and professional cleaning: Even with UV, plan professional coil and drain pan cleaning annually or as needed based on inspections. UV reduces regrowth but does not eliminate the need for periodic mechanical cleaning.

Safety practices

  • Avoid direct exposure: UV-C can damage skin and eyes. Coil-mounted and in-duct lamps should be positioned so occupants are not directly exposed. Access panels should have interlocks or warning labels.
  • Follow manufacturer and industry guidelines: Use proper ballasts, controls, and safety interlocks. Electrical work should meet local code and be performed by qualified technicians.
  • Ozone considerations: Some lamp types or aging lamps can produce ozone. Use lamps specified as low-ozone for occupied spaces to prevent respiratory irritation.
  • Personal protective equipment: Technicians performing maintenance should wear appropriate eye and skin protection and follow safe work practices.

Integration with existing HVAC systems

UV systems are commonly retrofitted to existing furnaces, air handlers, and ductwork. Key integration points:

  • Electrical supply: Verify available power at the installation location and that ballasts and controls are compatible.
  • Physical access: Coil-mounted lamps require access to the air handler or evaporator coil area. In-duct units need sufficient straight duct runs for proper mounting and exposure.
  • Controls: UV systems can be tied to system power so lamps only run when the air handler is on, or they can run continuously depending on design and goals.
  • Compatibility with filtration and humidification: Coordinate UV placement with filters and humidifiers to avoid unexpected interactions and maintain overall IAQ strategy.
MAINTENANCE PLAN

Maintenance Plan

SILVER PLAN (Heating & cooling packages

Our Silver Plan provides you with year-round, worry-free protection. The benefits include:

$129.95

/plan cost every 6 months

  • Inspection and cleaning of your system during service visits.

  • Next-day scheduling & 24-hour emergency service.

  • Full coverage for labor on repairs due to equipment failure.

  • 15% Discount on all parts for repairs and upgrades.

  • 15% Discount on additional system installation.

Get Started!
Two large industrial HVAC units with fans on a rooftop under a clear blue sky.

2

visits per year

1

year in duration

15%

discount on jobs

Orange snowflake with dark blue outline on a white background.

Cooling

  • Lubricate motors

  • Clean condensate line

  • Check fan belts

  • Check performance of system

  • Change filters

  • Check contactor points

  • Check evaporator air temperatures

  • Check pressure switches

  • Check wiring & connections

  • Clean condenser coil

  • Check refrigerant charge

  • Check temperature differential

  • Check operating pressures

  • Check evaporator coil

  • Check voltage and AMP draw

Graphic of an orange and black ship wheel with eight spokes on a white background.

Heating

  • Lubricate motors

  • Check wiring & connections

  • Adjust controls if needed

  • Clean burners/flame sensor.

  • Adjust combustion air to burners

  • Check Ohms and amps of furnace

  • Check blower

  • Check heat exchanger for cracks (if accessible)

  • Change filters, standard pleated filters included

  • Check performance of system

  • Check air temperature rise

  • Check C.O. levels

TESTIMONIALS

WHAT OUR CLIENTS HAVE TO SAY ABOUT US

Very please with the work done to my condo AC unit. Work was professional and described in detail what happened and what was done. I would definitely recommend! I will be using them for future services!
Crystal B.
Service installers were excellent. Very personable and professional. Informative and asked multiple times if we had any questions. Thanks to Jordan, Tyler, and Nick who went above and beyond, spending hours making sure everything was done right and working properly.
Margie G.
Extremely happy with my service! Technician Nicholas W. was professional and courteous throughout. He answered all of my questions and was on time which I love! Thank you for being reliable and trustworthy.
Amber T.
Thanks so much for your immediate response for my electrical issue after all the rain. Nick was very informative and completed the job immediately. So appreciative of your service!! Extremely reasonable cost.
Lieutenant C.
Called about getting an estimate on a mini split and got it installed promptly. My installer was very professional and helpful. Any questions I had were answered during and after the service.
Vivian E.
Great friendly professional service. Nicolas the technician that assisted me was very professional, knowledgeable, helpful, trustworthy. I will recommend this company. Thank you for your excellent service
Abraham B.