UV Air Treatment in Sheboygan Falls, WI
UV Air Treatment in Sheboygan Falls, WI
Ultraviolet (UV-C) air treatment is a proven option for improving indoor air quality in Sheboygan Falls homes and businesses. By using germicidal UV light installed in ductwork or aimed at evaporator coils and drain pans, UV systems reduce microbial growth that contributes to musty odors, coil efficiency loss, and airborne pathogen circulation. For homeowners in northeastern Wisconsin—where humid summers, lake-effect moisture, and older HVAC equipment increase the risk of mold and microbial buildup—UV-C treatment can be an effective component of a broader indoor air quality strategy.

Why choose UV-C for Sheboygan Falls homes
- High summer humidity near Lake Michigan increases coil condensation and microbial growth on HVAC surfaces.
- Seasonal temperature swings and tight, energy-efficient building envelopes can reduce natural air exchange, concentrating indoor contaminants.
- UV-C complements filtration and ventilation strategies to address microbes on surfaces and in air streams where filters are less effective.
Common issues UV air treatment addresses
- Microbial growth on coils and drain pans that reduces system efficiency and causes musty odors.
- Biofilm buildup on surfaces that traps dust and reduces heat transfer, increasing energy use.
- Recurring airborne allergens and microbes (mold spores, some bacteria, viruses) that are not fully captured by filters alone.
- Maintenance challenges for older HVAC units where frequent coil cleanings are disruptive or costly.
Types of UV air treatment and recommended placement
- Coil-mounted UV (coil-direct): Lamps mounted inside the air handler, facing the evaporator coil and drain pan. This is the most common and effective placement to keep coils clean and maintain heat transfer efficiency.
- In-duct UV: Lamps installed within supply or return ductwork to treat moving air. Best for targeting airborne microorganisms when placed in longer duct runs with adequate exposure time.
- Upper-air UV: Ceiling-mounted units that disinfect air in occupied spaces. Used in commercial or high-occupancy settings rather than typical residential systems.
Recommended placement for Sheboygan Falls systems:
- Position lamps to directly irradiate the wet coil face and drain pan for maximum biofilm control.
- For larger or multi-zone systems, use multiple lamps spaced to ensure uniform irradiance across the coil surface.
- In-duct systems should be placed where air velocity and exposure time provide an adequate UV dose—near the air handler or in long straight runs, avoiding immediate bends or obstructions.
Lamp specifications and selection
- Wavelength: Use germicidal lamps that emit UV-C near 254 nm (253.7 nm) for effective microbial inactivation. Choose ozone-free lamps specifically labeled as non-ozone producing.
- Lamp type: Low-pressure mercury lamps are the industry standard because of their reliable output. UV-C LED technology exists but currently offers lower output and higher cost for HVAC-scale applications.
- Power and count: Typical residential coil-mounted lamps range from 15W to 30W per lamp. Large commercial coils may require multiple 30W+ lamps. Final sizing depends on coil surface area, airflow, and the desired inactivation level.
- Ballasts/drivers: Use compatible electronic ballasts or drivers rated for continuous operation in HVAC environments.
Compatibility with HVAC systems
- Compatible with most central forced-air furnaces, air handlers, and rooftop packaged units when there is access to the coil or duct.
- Ductless mini-split systems may have limited space; coil-directed UV installation is sometimes possible in indoor units but should be evaluated to avoid warranty issues or material degradation.
- Confirm with equipment manufacturers when concerned about warranty implications, and ensure electrical wiring meets code for lamp installation.
Expected effectiveness and realistic results
- When properly sized and positioned, coil-mounted UV systems commonly achieve substantial reductions in surface microbial loading—frequently greater than 80-90% on treated surfaces—helping restore coil efficiency and reduce odor.
- Airborne reductions vary based on ventilation, filtration, and exposure time. Typical airborne microbe reductions are in the range of 30-70% when UV is combined with effective filtration and proper ventilation rates.
- UV is most effective as part of a layered approach: filtration (MERV 8–13 or higher as appropriate), adequate ventilation (fresh air exchange), humidity control, and routine maintenance.
Safety, certifications, and testing
- Safety: UV-C is harmful to skin and eyes. Systems must be installed to prevent occupant exposure: lamps enclosed in ductwork, interlocked access panels, or properly positioned upper-air units. Lamps should be labeled, and power should be disconnected before maintenance.
- Certifications: Look for UL or ETL listings for electrical safety of the UV assembly and ISO 15858 compliance for UV-C device safety where applicable. Manufacturer-provided test data and third-party laboratory results demonstrating germicidal efficacy are important for assessment.
- Testing: Verified installation includes measuring UV intensity at target surfaces with a calibrated UV-C meter and documenting levels against manufacturer dosing recommendations. Microbial surface sampling (e.g., ATP testing or culture-based assays) before and after installation can quantify performance.
Maintenance and lamp replacement intervals
- Lamp life: Low-pressure UV-C lamps typically lose effective output over time and are commonly replaced every 9 to 12 months for optimal performance. Some manufacturers recommend annual replacement.
- Cleaning: UV lamps and protective sleeves should be cleaned periodically—generally every 3 to 6 months—because dust and film reduce UV transmission. Frequency depends on system exposure and environmental conditions.
- LEDs: UV-C LED modules have longer rated lifespans but may have lower initial output; follow manufacturer guidance for replacement and driver maintenance.
- Electrical components: Inspect ballasts, wiring, mounts, and safety interlocks annually. Replace any degraded components promptly to maintain dosing and safety.
Combining UV with filtration and ventilation
- Filtration: Pair UV with a properly sized MERV-rated filter. Filters capture particulates and larger spores, while UV targets surface-associated microbes and reduces biofilm that filters cannot address.
- Ventilation: Maintain appropriate fresh air exchange to dilute indoor contaminants. UV reduces microbial loads but does not substitute for adequate outdoor air ventilation.
- Humidity control: Keeping relative humidity in Sheboygan Falls homes between 40–50% reduces mold growth susceptibility and maximizes overall IAQ benefits from UV treatment.
What to expect from a professional installation
- A qualified technician will perform a site assessment, inspect coil accessibility and duct layout, calculate required UV dose, and specify lamp type and quantity.
- Installation includes secure mounting, electrical hookups to existing power or new circuits as required, safety interlocks or access labels, and post-install intensity verification with a UV-C meter.
- The installer should provide documentation on lamp types, replacement schedule, and recommended maintenance intervals.
Long-term benefits for Sheboygan Falls residents
- Cleaner coils and drain pans, leading to improved HVAC efficiency and potentially lower energy use.
- Reduced musty odors and fewer microbial-related maintenance calls.
- Improved overall indoor air quality when UV is combined with filtration and ventilation improvements—especially valuable in humid summer months and tightly sealed homes common in the region.
UV air treatment is a targeted, science-backed tool for reducing microbial growth and supporting healthier indoor environments in Sheboygan Falls. When specified, installed, and maintained correctly—alongside filtration, humidity control, and proper ventilation—UV-C systems offer measurable benefits for system performance and occupant comfort.
Maintenance Plan
SILVER PLAN (Heating & cooling packages
Our Silver Plan provides you with year-round, worry-free protection. The benefits include:
$129.95
/plan cost every 6 months
Inspection and cleaning of your system during service visits.
Next-day scheduling & 24-hour emergency service.
Full coverage for labor on repairs due to equipment failure.
15% Discount on all parts for repairs and upgrades.
15% Discount on additional system installation.

2
visits per year
1
year in duration
15%
discount on jobs
Cooling
Lubricate motors
Clean condensate line
Check fan belts
Check performance of system
Change filters
Check contactor points
Check evaporator air temperatures
Check pressure switches
Check wiring & connections
Clean condenser coil
Check refrigerant charge
Check temperature differential
Check operating pressures
Check evaporator coil
Check voltage and AMP draw
Heating
Lubricate motors
Check wiring & connections
Adjust controls if needed
Clean burners/flame sensor.
Adjust combustion air to burners
Check Ohms and amps of furnace
Check blower
Check heat exchanger for cracks (if accessible)
Change filters, standard pleated filters included
Check performance of system
Check air temperature rise
Check C.O. levels