Surge Protection Maintenance in Cedarburg, WI
Surge Protection Maintenance in Cedarburg, WI
Power surges are a common but often overlooked threat to Cedarburg homes. Summer thunderstorms, lightning strikes, utility switching, and even heating and air conditioning cycles can produce transient voltage spikes that damage electronics, shorten appliance lifespans, and create safety hazards. Surge protection maintenance focuses on keeping whole-house surge protective devices (SPDs) and point-of-use protectors functioning correctly so your panels, appliances, and sensitive electronics remain protected when it matters most.

Why surge protection maintenance matters in Cedarburg, WI
Cedarburg experiences seasonal extremes: strong summer storms with lightning and microbursts, spring and fall utility switching, and cold winters that put heavy loads on heating systems. Those conditions increase the likelihood and impact of transient surges. Regular maintenance:
- Verifies that whole-house SPDs and point-of-use devices still provide protection after storms or age-related wear.
- Detects damaged MOVs or failed SPD modules before they fail silently.
- Ensures grounding and bonding are intact, which is critical for SPD performance and safety.
- Preserves warranties and helps with insurance documentation after a claim.
Common surge protection issues we inspect
A maintenance inspection looks for common failure modes and installation problems that reduce protection effectiveness:
- Degraded or failed MOVs (metal-oxide varistors) inside SPD units
- Blown or tripped SPD modules or indicator lights showing end-of-life
- Loose or corroded connections at the main service panel or SPD terminals
- Inadequate or deteriorated grounding and bonding
- Incorrectly sized or improperly located SPDs (wrong type for service)
- Missing point-of-use protection for sensitive electronics
- Heat damage, discoloration, or signs of arcing around the panel
What a typical surge protection maintenance service includes
Inspections and tests are performed with industry-standard tools and manufacturer guidelines to assess protective capacity and safety:
- Visual inspection of the service entrance, main panel, and subpanels for physical damage, discoloration, or loose terminations.
- Check SPD status indicators and replace modular cartridges or units showing end-of-life.
- Test grounding and bonding continuity and measure ground resistance when required to ensure a low-impedance path for surge dissipation.
- Verify correct wiring and location of whole-house SPD relative to the main breaker for optimal clamping performance.
- Inspect and test point-of-use devices at sensitive locations (home office, entertainment center, furnace/AC control boards).
- Thermal imaging of panel connections to reveal hot spots from loose or corroded lugs that may impair SPD operation.
- Documentation of measured values, visual findings, and recommended actions for future reference and insurance needs.
Diagnosing damaged components (MOVs, SPD modules)
MOVs and SPD modules are sacrificial devices: they absorb energy and degrade over time. Diagnosis includes:
- Visual and electrical testing of SPD indicators and removable cartridges where applicable.
- Measuring voltage presence and continuity across SPD terminals to ensure proper operation.
- Identifying discoloration, cracking, or odors that indicate thermal stress or prior surge events.
- Assessing the cumulative energy exposure of SPDs—multiple moderate surges can degrade MOVs even if no single event caused a failure.
Technicians will flag SPDs that no longer meet manufacturer specifications or that show signs of irreversible degradation and recommend replacement.
Recommended replacement intervals and end-of-life signs
Replacement timing depends on exposure and device type, but general guidance:
- Whole-house SPDs: inspect annually; consider replacement every 5 to 10 years or sooner if the device shows end-of-life indicators or has endured a major surge event.
- Point-of-use protectors: inspect every 1 to 3 years depending on quality and local surge exposure; replace immediately if indicator lights fail or smoldering/heat marks are present.
- Replace modular SPD cartridges immediately when indicator shows failure; replace entire unit if not serviceable or if manufacturer recommends.
End-of-life signs: persistent tripped indicators, visible damage to the housing or MOVs, frequent unexplained appliance failures, or thermal discoloration in the panel.
Steps to improve overall electrical protection in your home
Surge protection maintenance often reveals opportunities to strengthen protection. Recommended steps commonly include:
- Installing or upgrading a Type 1/Type 2 whole-house SPD at the main service entrance for first-line defense.
- Adding Type 3 point-of-use protection at TVs, computers, routers, home theater, and HVAC control boards for layered defense.
- Upgrading grounding electrodes and bonding connections to reduce impedance and improve SPD effectiveness.
- Relocating SPDs closer to the service disconnect and using appropriately sized conductors for surge current paths.
- Replacing aging or undersized SPDs with modern, higher-capacity units rated for expected transient energy.
- Coordinating surge protection across subpanels, detached garages, and outbuildings to avoid protection gaps.
Benefits for electronics, appliances, and safety
Properly maintained surge protection yields clear, measurable benefits:
- Extended life for sensitive electronics like computers, TVs, and smart home devices.
- Reduced risk of costly appliance failures for refrigerators, furnaces, air handlers, and washers/dryers.
- Lower probability of electrical fires caused by surge-induced arcing or overheating.
- Predictable performance of critical systems such as sump pumps, security systems, and medical equipment.
- Documentation-ready inspection reports useful for warranty claims or insurance submittals.
Service agreements and storm response for Cedarburg homeowners
A maintenance-focused service agreement gives Cedarburg homeowners consistent protection and faster response when it matters most. Typical elements of a maintenance agreement:
- Scheduled inspections: annual or biannual checks of whole-house SPDs and key point-of-use devices.
- Priority post-storm evaluations: surge events or lightning storms prompt rapid diagnostic visits to assess SPD function and replace failed components.
- Clear documentation: written reports detailing inspection findings, test results, parts replaced, and recommended upgrades for records and insurance.
- Parts and labor options: planned replacement of modular cartridges and SPDs with compatible, code-compliant equipment.
- Coordination with appliance service and warranties to minimize downtime for damaged equipment.
Service agreements provide predictability and peace of mind for Cedarburg residents living with seasonal storm exposure and winter electrical stress.
Practical maintenance tips for homeowners
Small actions between professional visits can preserve protection:
- Keep a list of high-value electronics and their locations for focused point-of-use protection.
- Replace cheap, worn power strips with UL-listed point-of-use protectors that show status indicators.
- After any visible lightning strike or severe storm, schedule an inspection to confirm SPD health.
- Avoid DIY panel work; proper SPD performance depends on correct installation and bonding.
Regular surge protection maintenance protects your home against invisible risks and helps ensure your investments in electronics and appliances last longer. For Cedarburg homes, where storms and seasonal electrical stresses are common, a proactive maintenance plan is a practical step toward safer, more reliable electrical protection.
Maintenance Plan
SILVER PLAN (Heating & cooling packages
Our Silver Plan provides you with year-round, worry-free protection. The benefits include:
$129.95
/plan cost every 6 months
Inspection and cleaning of your system during service visits.
Next-day scheduling & 24-hour emergency service.
Full coverage for labor on repairs due to equipment failure.
15% Discount on all parts for repairs and upgrades.
15% Discount on additional system installation.

2
visits per year
1
year in duration
15%
discount on jobs
Cooling
Lubricate motors
Clean condensate line
Check fan belts
Check performance of system
Change filters
Check contactor points
Check evaporator air temperatures
Check pressure switches
Check wiring & connections
Clean condenser coil
Check refrigerant charge
Check temperature differential
Check operating pressures
Check evaporator coil
Check voltage and AMP draw
Heating
Lubricate motors
Check wiring & connections
Adjust controls if needed
Clean burners/flame sensor.
Adjust combustion air to burners
Check Ohms and amps of furnace
Check blower
Check heat exchanger for cracks (if accessible)
Change filters, standard pleated filters included
Check performance of system
Check air temperature rise
Check C.O. levels