Ventilation Systems in Richfield, WI
Ventilation Systems in Richfield, WI
Keeping indoor air clean and moisture under control is essential for comfortable, healthy homes and businesses in Richfield, WI. With cold winters, humid summers, and tightly built modern houses, mechanical ventilation systems - ERVs, HRVs, exhaust and supply systems - are often the most effective way to deliver fresh air, manage humidity, and protect building durability.

What mechanical ventilation systems do
Mechanical ventilation moves controlled volumes of outdoor air into and out of a building to maintain indoor air quality and manage moisture. Common types include:
- ERV (Energy Recovery Ventilator) - exchanges heat and a portion of moisture between incoming and outgoing air. Good for year-round use in climates with both cold winters and humid summers.
- HRV (Heat Recovery Ventilator) - exchanges sensible heat only, recovering warmth in winter while exhausting stale indoor air. Best in cold, dry conditions.
- Exhaust-only systems - use fans to remove stale air (bathroom, kitchen) and rely on make-up air through passive vents or infiltration.
- Supply-only systems - bring in filtered outside air, sometimes with local heating, and rely on exhaust through passive vents.
- Balanced systems - combine supply and exhaust flows to control where air moves, reducing drafts and humidity problems.
Common ventilation issues in Richfield homes and businesses
- Persistent condensation on windows and in basements during cold months
- Musty smells and elevated humidity in basements or crawlspaces
- Cooking, bathroom, and pet odors that linger
- Dust and allergens circulating in homes that are tightly sealed
- Ice formation or frosting in poorly designed heat recovery units during deep cold
Why balanced ventilation matters in Richfield, WI
Balanced ventilation (matching supply and exhaust) is the most reliable way to control indoor air quality and moisture without creating negative or positive pressure problems. In Richfield:
- Cold winters increase the risk of condensation and mold when humid indoor air contacts cold surfaces. Balanced systems with heat or energy recovery reduce that risk.
- Humid summers can load a building with moisture; ERVs help limit incoming moisture while keeping fresh air flowing.
- Tighter building envelopes used in energy-efficient construction make passive ventilation insufficient; mechanical balanced systems ensure code-compliant air exchanges.
System selection and sizing
Choosing the right system depends on building type, occupancy, envelope tightness, and specific IAQ goals. Key considerations:
- Follow ASHRAE 62.2 ventilation rates for residences and local commercial ventilation standards for businesses. These standards set required CFM per occupant and per square foot.
- Perform a load and ventilation calculation using room counts, bedrooms, square footage, and occupancy patterns to determine required CFM.
- For most single-family homes in this region, a balanced ERV sized to provide continuous ventilation at ASHRAE 62.2 rates is common. Larger or multi-zone homes and commercial spaces may need ducted systems with zone controls.
- Consider filter efficiency for incoming air (MERV ratings) based on allergy concerns and outdoor particulate levels.
Installation and ductwork considerations
Proper installation is critical to performance and durability.
- Locate intakes away from exhausts, driveways, and roof vents to prevent exhaust re-entry.
- Design duct runs to minimize bends and long horizontal runs; use insulated ducts in unconditioned spaces to prevent condensation.
- Provide condensate drainage and freeze protection for HRV/ERV units, especially in unheated attics or garages.
- Ensure fresh air is distributed to living spaces and exhaust points are at pollutant sources such as kitchens and bathrooms.
- Integrate controls so the system can run continuously at a low rate and boost for higher pollutant loads or occupancy.
Energy recovery features and efficiency
Energy recovery reduces operating costs and improves comfort.
- Sensible heat recovery recovers temperature differences; total energy recovery (enthalpy) recovers both heat and moisture.
- ERVs are particularly effective in climates with hot, humid summers and cold winters by limiting moisture transfer while still recovering energy.
- Look for units with high sensible recovery efficiency and low fan power draw to minimize electrical use.
- Defrost or bypass strategies are important for cold-weather performance to avoid icing in winter.
Controls and maintenance
Routine maintenance keeps systems efficient and reliable.
- Replace or clean filters according to manufacturer recommendations; typical residential intervals are every 3-12 months depending on filter efficiency and indoor pollutant loads.
- Inspect heat exchangers annually and clean as needed to maintain recovery efficiency.
- Verify condensate drains and pans are clear and functional to prevent water damage.
- Check fans and motors for wear and confirm control settings seasonally to match occupancy patterns.
- Consider programmable or smart controls that adjust ventilation based on occupancy, CO2, or humidity levels.
Code compliance and incentives in Richfield, WI
- Mechanical ventilation should meet ASHRAE 62.2 for residential projects and applicable local commercial codes. Local building officials in Washington County may reference state codes that require verified ventilation rates for new construction or major renovations.
- Energy and efficiency incentives may be available through state or utility programs such as Focus on Energy, and broader energy efficiency incentives may apply at the federal level. Eligibility typically depends on system efficiency, installation practices, and whether the work is part of a larger energy upgrade.
Practical examples
- Example 1 - Typical Richfield townhouse: 3-bedroom, tight envelope, frequent indoor humidity in winter. Recommended solution - a ducted ERV sized to ASHRAE 62.2 with MERV 8-11 incoming filtration and programmable low/high ventilation speeds.
- Example 2 - Small commercial office: Open-plan office with 12 occupants and occasional conference use. Recommended solution - balanced supply and exhaust with energy recovery and demand-controlled ventilation using CO2 sensors to reduce runtime during low occupancy.
- Example 3 - Older farmhouse with damp basement: Focus on basement source control plus a supply ventilation strategy to pressurize and dry the lower level, potentially combined with an ERV for living areas.
Final notes on benefits and long-term value
A properly selected and installed mechanical ventilation system improves indoor air quality, reduces moisture-related risks, enhances comfort, and supports energy-efficient operation in Richfield homes and businesses. When planning a system, prioritize accurate sizing, well-designed ductwork, and serviceable access to controls and filters. Coordinating ventilation upgrades with insulation, air sealing, and HVAC work yields the best results for durability and comfort in Wisconsin’s seasonal climate.
Maintenance Plan
SILVER PLAN (Heating & cooling packages
Our Silver Plan provides you with year-round, worry-free protection. The benefits include:
$129.95
/plan cost every 6 months
Inspection and cleaning of your system during service visits.
Next-day scheduling & 24-hour emergency service.
Full coverage for labor on repairs due to equipment failure.
15% Discount on all parts for repairs and upgrades.
15% Discount on additional system installation.

2
visits per year
1
year in duration
15%
discount on jobs
Cooling
Lubricate motors
Clean condensate line
Check fan belts
Check performance of system
Change filters
Check contactor points
Check evaporator air temperatures
Check pressure switches
Check wiring & connections
Clean condenser coil
Check refrigerant charge
Check temperature differential
Check operating pressures
Check evaporator coil
Check voltage and AMP draw
Heating
Lubricate motors
Check wiring & connections
Adjust controls if needed
Clean burners/flame sensor.
Adjust combustion air to burners
Check Ohms and amps of furnace
Check blower
Check heat exchanger for cracks (if accessible)
Change filters, standard pleated filters included
Check performance of system
Check air temperature rise
Check C.O. levels